Contact for installers: +7 (8452) 22-11-40
EN RU KZ

RM-1 prot.R3, RM-1S prot.R3, RM-4 prot.R3

RM-1 prot.R3, RM-1S prot.R3, RM-4 prot.R3
RM-1 prot.R3, RM-1S prot.R3, RM-4 prot.R3
Addressable relay module RM-1 prot.R3, RM-1S prot.R3, RM-4 prot.R3 is intended for control of actuators incorporated into fire alarm systems. It is designed to operate as a part of address system controlled by receive-control alarm device Rubezh-2OP prot.R3.
Power supply from DCL (24 - 36 V)
Number of relay outputs in RM-1 prot.R3/ RM-1S prot.R3/ RM-4 prot.R3 1 / 1 / 4
Current consumption in standby mode of RM-1 prot.R3/ RM-1S prot.R3/ RM-4 prot.R3, no more than:
0,18 m / 0,4 m / 0,38 m
Each relay of RM-1 prot.R3 and RM-4 prot.R3 can switch:
direct current of 24 V
alternating current of 230 V
Each relay of RM-1S prot.R3 module is commuting the current:
direct current of 24 V
alternating current of 230 V

from 2
from 0,25

from 5
from 5
Overall dimensions of R-1 prot.R3 module, no more than 525224 mm
Weight of R-1 prot.R3 module, no more than 28 g
Overall dimensions of the modules RM-1S prot.R3 / RM-4 prot.R3, no more than 1257837 mm
Weight of RM-1S prot.R3 / RM-4 prot.R3, no more than 100 g
Operating temperature range -25 to +55
Average service life, at least 10 years

Addressable relay module is a programmable device. It is configured by the user when configuring the system from a computer or from a control and indicating device.

Relay module is a remotely operated switch. Functionally, relay module RM-4 prot.R3 represents four separate logical units (four separate relays) each having its own address in the system.

Addressable relay module allows connection of any actuators of PCS which can be controlled on relay level, provided their current and voltage meet the technical characteristics of the relay. Besides, relay module enables transmission of different system states to external equipment and central monitoring console.

Relay module has LED indication of communication with control and indicating device and indication of the activated state of the relay.

Address mark power supply as well as signals transmission to receiving and controlling device is realized via a unipolar communication line.

Relay module RM-1 prot.R3, RM-1S prot.R3, RM-4 prot.R3 may be installed in DIN rail using special securing bar (not in the scope of supply; may be provided by separate order).

Relay activation can be caused by different events in the system (zone), e.g., fire, warning, activation of fire-suppression module automatics, alarm, arming, disarming, lamp, devices actuation (AM-1T, MDU-1, ShUZ) etc.


Back to list