Rubezh-2OP prot.R3

Rubezh-2OP prot.R3
The addressable security and fire alarm system controller PPKOPU Rubezh-2OP prot. R3 is designed for operation in addressable security and fire alarm systems. Control panel PPKOPU Rubezh-2OP prot. R3 designed for using in systems of addressed fire alarm, security, extinguishing, smoke removal, alerting and access control. With Rubezh-2OP prot. R3 possible to build the distributed addressed system of fire alarm and security, and integrate therein until 60 panels. To every control panel possible to connect 500 addressable Rubezh™ devices.
Supply voltage 12 V DC
Intrinsic current consumption, no more than
Current consumption, in case of connection of 500 addressable devices, no more than
0,4 А
1 А
Output characteristics of electrical-mechanical relay 1:
DC / AC voltage switch
maximum switching current

30/250 V
3 А
Output characteristics of solid-state relay 2 and 3
DC / AC voltage switch
maximum switching current

125 V
0,1 А
Characteristics of the outputs 4 and 5, with continuity test of a load circuit
DC voltage output
maximum load output current

U out. = U supply - 1
300 mА
Number of external interfaces for data exchange and programming:
of RS-485 type
of USB type

1
1
Number DCL, connected to the unit: 2
length DCL, no more than
Cable of RS485 interface, no more than
Cable of USB interface
3000 m
1000 m
to 3 m
Maximum number of the addressable devices connected to the unit: 500
Output voltage of an dedicated communication line 24 to 36 V
Overall dimensions, no more than 200х160х50 mm
Weight, no more than 1 kg
Operating temperature range from 0 to +55°С
The unit keeps an event log where the event type, date, time, and the device address are recorded. All events are stored in non-volatile memory and can be read out with the use of the keyboard and the display located on the unit front. The log is divided into three parts: main log, security log, and ACS device log. All events related to survivability of the system (failure of the devices, loss of connection with the devices) and execution of main (i.e. fire protection) functions by the unit (Fire 1, Fire 2, device enable/disable, scenario realization) are recorded in main log.

The main functions of the device "Rubezh-2OP" prot. R3:

  • receiving signals from addressable devices via an address communication line; 
  • the inclusion of remote alarm devices in the event of an alarm and fire; 
  • management of fire extinguishing and smoke removal systems, voice notification at the protected object; access control system management; automatic control of the integrity of the DCL and the health of address devices; 
  • centralized control of several subordinate devices "Rubezh-2OP" protr. R3. symbolic indication of received signals; light-sound indication signaling mode; data exchange via RS-485 interface with other devices and a computer; USB data exchange with a computer.